Provenance record

Matched but Not Better: An Equivalence-Tested Benchmark of Quantum Machine Learning on Six Clinical Datasets and the QML-Health-READY Reporting Framework

arXiv cs.LG (Machine Learning) (tier 1, academic) 2026-11-05T05:00:00.000Z Original ↗

Source note: Preprints. High volume; heavily filtered at triage.


Discourse valence
-25
Adverse
confidence 80% · 1 item
Adverse readingFavourable reading
Single-model reading. This item did not meet the threshold for a multi-model panel.
Evaluation and measurementMedicine and healthScientific acceleration
Excerpt as ingested

arXiv:2611.05442v1 Announce Type: new Abstract: Background: Quantum machine learning (QML) is promoted for clinical prediction, but comparisons with classical models are rarely paired or tested for equivalence. Methods: We compared a quantum-kernel support vector machine (QSVM; 4 qubits, tuned bandwidth) and a variational quantum classifier (VQC) with five tuned classical models across six public clinical datasets. All models used identical four-component inputs and 25 cross-validation splits. Paired AUROC differences were assessed using a corrected resampled t-test, Holm-adjusted equivalence tests (margins: +/-0.02 and +/-0.05), and random-effects pooling. Ablation, noise, finite-shot, and implementation-fault analyses were conducted. We propose QML-Health-READY, an eight-domain reporting framework. Results: Neither quantum model significantly outperformed any classical comparator. Pooled across datasets, QSVM differed from the kernel-matched radial basis function (RBF) SVM by -0.006 AUROC (95% CI: -0.017 to +0.004), equivalent to +/-0.02. VQC differed from the best classical model by -0.007 (95% CI: -0.019 to +0.004). QSVM was equivalent to RBF SVM within +/-0.05 in four of six datasets but was significantly worse than the best classical model on NHANES 2017-18 (-0.076). A classically trivial product-state kernel performed as well as the entangling kernel. With depolarizing noise (p = 0.01) and 1,024 shots per kernel entry, QSVM AUROC decreased by 0.054 (95% CI: 0.036 to 0.071). Untuned bandwidth produced near-chance AUROC (0.48-0.59). Conclusions: Correctly configured qu

Every model that read this

ModelProviderStageScoreConf.LatencyPromptWhen
Llama 3.3 70BMetaanalysis -25 80%4363ms v1.0.0 / m1.0.1 2026-11-05 05:42
Llama 3.3 70B · reading

Quantum machine learning models did not outperform classical models in clinical prediction tasks, and had significant practical costs.

evidence: primary horizon: n/a

Evidence extracted

The chain
SOURCE     arXiv cs.LG (Machine Learning) (tier 1)
   ↓
DOCUMENT   8a9c45ff-3df6-4721-bb73-e3f6aebdb14f
           https://arxiv.org/abs/2611.05442
   ↓
EVIDENCE   2 extracted excerpts
   ↓
MODEL RUN  1 run, methodology 1.0.1
   ↓
SCORE      -25  (Adverse)
   ↓
CONFIDENCE 80%